Doors & Windows Archives - SYKON GmbH https://sykon.ae/category/doors-windows/ GERMAN ENGINEERING SINCE 1967 Sat, 13 Feb 2021 09:34:37 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.1 https://sykon.ae/wp-content/uploads/2020/11/cropped-SYKON-LOGO-512X512-32x32.jpg Doors & Windows Archives - SYKON GmbH https://sykon.ae/category/doors-windows/ 32 32 SMOKE PROTECTION DOORS-SP60 https://sykon.ae/smoke-protection-doors-sp60/ https://sykon.ae/smoke-protection-doors-sp60/#respond Sat, 23 Jan 2021 08:58:54 +0000 https://sykon.ae/?p=1659 SYKOTHERM-S75l SYKOTHERM-S70l SUPERIOR-S60l SUPERIOR-S45l SMOKE PROTECTION-SP60l SYKOTHERM BR-110 SYKOTHERM-SL007 SUPERIOR-SL450 SUPERIOR-SL400 BI-FOLD-S75 SUPERIOR-SY-50/60 SYK-80-UNITIZED SMOKE PROTECTION DOORS acc. to DIN 18095 + EN 1634 SP60 SP60 is a hinge system suitable for the construction of entrance doors, interior fittings, partition walls, cabins, wind/ weather protection elements, etc. The high-quality smoke protection doors required to comply […]

The post SMOKE PROTECTION DOORS-SP60 appeared first on SYKON GmbH.

]]>

SMOKE PROTECTION DOORS acc. to DIN 18095 + EN 1634

SP60

SP60 is a hinge system suitable for the construction of entrance doors, interior fittings, partition walls, cabins, wind/ weather protection elements, etc. The high-quality smoke protection doors required to comply with building regulations according to DIN/EN. To ensure that escape routes can be accessed in the event of fire, it may be necessary to use them in the following: – residential and office buildings – high-rise buildings – administrations, schools – nursing homes, hospitals – commercial buildings – accommodation and restaurants – industrial and commercial enterprise..

 

Construction depths.

Basic construction depth 60 mm.

 

Opening types.

Single or double-leaf hinged door, DIN left or DIN right, opening inwards or outwards. With skylights and side panels.

 

Fittings, accessories.

Screw-on, roller and concealed door hinges, hinge side protection, finger protection. Normal and panic function, panic crossbar fitting, escape door locks, escape route securing, integrated upper door closers, swing door drives, electric openers, magnetic contacts, and many more. ..

Construction type, testing:

Tested smoke protection doors in accordance with the design test in smoke tightness and continuous

function: DIN 18095 (Smoke protection, Germany) EN 1634-3 (Smoke protection, Europe) DIN 18650-1

(Machinery Directive) General building inspection test certificate Also tested for sash heights of 3.00 m and

more, and sash widths of 1.40 m and more.

Glazing and sealing profiles.

Glazing beads square or rounded, central glazing possible, sealing profiles EPDM quality according to

DIN 7863 (black) or silicone rubber (white).

  • Certified system performance by the IFT Rosenheim Institute..
  • Smoke protection door acc. to DIN 18095

The post SMOKE PROTECTION DOORS-SP60 appeared first on SYKON GmbH.

]]>
https://sykon.ae/smoke-protection-doors-sp60/feed/ 0
SUPERIOR S45 https://sykon.ae/superior-s45/ https://sykon.ae/superior-s45/#respond Sat, 23 Jan 2021 08:28:28 +0000 https://sykon.ae/?p=1618 SYKOTHERM-S75l SYKOTHERM-S70l SUPERIOR-S60l SUPERIOR-S45l SMOKE PROTECTION-SP60l SYKOTHERM BR-110 SYKOTHERM-SL007 SUPERIOR-SL450 SUPERIOR-SL400 BI-FOLD-S75 SUPERIOR-SY-50/60 SYK-80-UNITIZED NON INSULATED HINGED SYSTEM SUPERIOR S45 S45 is one of the most complete non insulated casement systems designed according to European standard which can server a wide range of typologies and satisfying the performance targets. Profiles with curved and flat designs […]

The post SUPERIOR S45 appeared first on SYKON GmbH.

]]>

NON INSULATED HINGED SYSTEM

SUPERIOR S45

sykon

S45 is one of the most complete non insulated casement systems designed according to European standard which can server a wide range of typologies and satisfying the performance targets. Profiles with curved and flat designs are available. It is compatible with Sykon ’s sliding and curtain wall system

Basic system depth 45 mm

Air permeability CLASS 4
Watertightness CLASS E900
Resistance to wind load RE2400
Sound reduction36 db
   
   
TECHNICAL CHARACTERISTICS
Visible aluminium face width104 mm
Frame height58 mm
Frame width45 mm
Sash height75 mm
Sash width52 mm
Sash weightUp to 130 Kg
Glazingup to 32mm

The post SUPERIOR S45 appeared first on SYKON GmbH.

]]>
https://sykon.ae/superior-s45/feed/ 0
SYKOTHERM-S75 https://sykon.ae/sykotherm-s75/ https://sykon.ae/sykotherm-s75/#respond Sun, 06 Dec 2020 13:47:41 +0000 https://sykon.ae/?p=938 SYKOTHERM-S75l SYKOTHERM-S70l SUPERIOR-S60l SUPERIOR-S45l SMOKE PROTECTION-SP60l SYKOTHERM BR-110 SYKOTHERM-SL007 SUPERIOR-SL450 SUPERIOR-SL400 BI-FOLD-S75 SUPERIOR-SY-50/60 SYK-80-UNITIZED HINGED INSULATED SYSTEM SYKOTHERM-S75 The Sykotherm S75 is a multi-chamber with thermal break system for windows & doors which suites to all modern aesthetics. Thermal break is made of high glass fibre reinforced polyamide. It has good thermal stability due to […]

The post SYKOTHERM-S75 appeared first on SYKON GmbH.

]]>

HINGED INSULATED SYSTEM

SYKOTHERM-S75

The Sykotherm S75 is a multi-chamber with thermal break system for windows & doors which suites to all modern aesthetics. Thermal break is made of high glass fibre reinforced polyamide. It has good thermal stability due to low shear bond. Thermal insulation zone can be upgraded by inserting additional EPS insulation cores. The Basic construction depth of this system is 75mm. This system offers single leaf, duo leaf hinged doors with DIN left or DIN right Positions which can open inward and outward or alternately escape/rescue/panic doors with 1 and 2 leaf options. S75 can provide high acoustic performance (Refer System Performance). This system has an option for concealed hinges which enhance aesthetic performance as well and option of 7-point locking which enhance the security. Apart from this lever handle in aluminium, stainless steel, overhead door closers etc. are the various options in fittings. The system development was driven by need for the best in class in terms of thermal insulation. Water tightness as well as sound reduction. The Sykotherm S75 is a perfect solution for mostdemanding markets.

Air permeability EN 1026, EN 12207CLASS 4
Watertightness EN 1027, EN 12208CLASS E1350
Resistance to wind load EN 12210, EN 12211CLASS C5/B5
Burglar resistance EN 1627-1630RC3
Thermal Insulation EN 10077-2Uw= 1,1 to 1,4 W/m2 K
Sound reduction EN 14351, EN 717Rw (C;Ctr) = 48 (-1;-3) db
Tags

The post SYKOTHERM-S75 appeared first on SYKON GmbH.

]]>
https://sykon.ae/sykotherm-s75/feed/ 0